Correlation Between Healthcare Practitioners Education and the Usability of Precordial ECG SafOne

Abstract

Performing electrocardiogram (ECG) recordings using the standard method presents a challenge to healthcare practitioners because of the need to precisely locate the six precordial electrodes or lead according to the six thoracic landmarks. A new method using precordial lead ECG SafOne was introduced to healthcare professionals and compared to the precordial lead standard. The study aims to identify the correlation between healthcare practitioners’ education and the usability of the precordial ECG SafOne. This study employed a quantitative descriptive design using a user-centered design survey method. Two hundred twenty-eight healthcare practitioners, including doctors and nurses from three hospitals in Pekanbaru, Riau, Indonesia, participated in this study and were selected using the purposive sampling technique. Evaluation variables assessment was collected using the precordial ECG SafOne questionnaire. The data analysis used was Spearman Rho to identify the correlation between the two variables investigated. Demographic data depicts that most of the participants were nurses 215 (94.2%), healthcare practitioners education background with Diploma 107 (46%), registered nurses 108 (47.4%), and Doctors 13 (5.7%), and average age was the early adult stage, 103 participants (45.2%). The bivariate analysis results show a correlation between healthcare practitioners’ education and usability of the precordial ECG SafOne with a p-value of 0.029 (p-value < 0.05). In conclusion, healthcare practitioners appraise the precordial ECG SafOne as an effective, applicable, practical, and renovate tool and valuable for electrocardiogram recordings in patients with cardiovascular diseases.


Keywords: education, usability, electrocardiography, SafOne, healthcare practitioners

References
[1] Cho Y, Kwon J myoung, Kim KH, Medina-Inojosa JR, Jeon KH, Cho S, et al. Artificial intelligence algorithm for detecting myocardial infarction using six-lead electrocardiography. Sci Rep. 2020;10(1):1–10.

[2] Bickerton M, Pooler A. Misplaced ECG electrodes and the need for continuing training. Br J Card Nurs. 2019;14(3):123–132.

[3] HS, MK. Design and development of ECG simulator and microcontroller based displayer. J Biosens Bioelectron. 2018;09(03).

[4] Dewi WN, Safri S, Rosma IH. Modified precordial lead ECG SafOne on electrocardiography recordings. Sci Rep [Internet]. 2022;12(1):1–8. Available from: https://doi.org/10.1038/s41598-022-12013-x

[5] Li M, Xiong W, Li Y. Wearable measurement of ECG signals based on smart clothing. Int J Telemed Appl. 2020;2020:9.

[6] Bansal A, Joshi R. Portable out-of-hospital electrocardiography: A review of current technologies. J Arrhythmia. 2018;34(2).

[7] Dewi WN, Safri, Hasyim I, Erwin. Development of precordial electrode pattern device for electrocardiogram (ECG) recording. Riau University; 2020.

[8] Wallisch A, Paetzold K. Methodological foundations of user involvement research: A contribution to user-centred design theory. In: Proceedings of the Design Society: DESIGN Conference. 2020.

[9] Němcová A, Smíšek R, Maršánová L, Smital L, Vítek M. A comparative analysis of methods for evaluation of ECG signal quality after compression. BioMed Research International; 2018. p. 1–26.

[10] Wong KC, Thiagalingam A, Kumar S, Marschner S, Kunwar R, Bailey J, et al. User perceptions and experiences of a handheld 12-Lead electrocardiographic device in a clinical setting: Usability evaluation. JMIR Cardio. 2021;5(2):1–16.

[11] Nadal C, Sas C, Doherty G. Technology acceptance in mobile health: Scoping review of definitions, models, and measurement. J Med Internet Res. 2020;22(7):1–17.

[12] Wu H. Retention of knowledge by nurses after an online ECG monitoring course [Internet]. ProQuest Dissertations and Theses. Yale University; 2012. Available from: http://elischolar.li-brary.yale.edu/ysndt/1018

[13] Tambariki KG, Kumaat LT, Silolonga WN. Lama masa kerja dan tingkat pendidikan perawat dengan penanganan pertama kejang demam pada anak. J Keperawatan. 2020;8(1):1–9.

[14] Triamanda F, Dewi WN, Woferst R. Placement time duration of precordial leads of ECG SafOne and standard ECG. J Keperawatan. 2021;12(1):123–128.

[15] Saputri ISY, Fadhli M, Surya I. Penerapan Metode UCD (User Centered Design) Pada E-Commerce Putri Intan Shop Berbasis Web. J Nas Teknol dan Sist Inf. 2017;3(2):269– 278.

[16] Marlisa, Pratiwi DN. Gambaran pengetahuan perawat tentang interpretasi EKG pada pasien aritmia di ruang ICCU RSUD dr pirngadi medan. J Ilm PANNMED (Pharmacist, Anal Nurse, Nutr Midwivery, Environ Dent. 2019;13(3):195–200.