Evaluation Of Operating Performance Of The Reactor Coolant System Of Rsg-Gas Using Chemcad6.1.4

Abstract

Evaluation of the operation of reactor main coolant system RSG-GAS is very important. This is related with the operation of the reactor that has been going on more than 27 years although the current reactor coolant system is still operating safely. The main coolant system RSG-GAS including both the primary and secondary cooling system. Evaluation can be conducted by calculating the coolant system performance by using the ChemCad6.1.4 software. Furthermore, this calculation result is compared with the most recent measurement in the cooling system operation. By this way it can be known the performance degradation in the Reactor Coolant System operation.The operating parameter data of primary and secondary cooling system are temperature, pressure and flow rate of coolant. The reactor operation at the power of 15 MW is used as a reference data.The calculation result shows that the temperature parameter between calculation by ChemCad and the measurement data qualitatively is no significant deviations. However in the secondary coolant system, the outlet pressure of both heat exchanger nozzles are 0.8bar and 1.2bar that indicate lower than the calculation results. It’s may be caused by the flow disturbances through the tube-side of heat exchangers. In generally the existing operating parameters on the reactor cooling system in terms of safety aspects still under safely condition.

References
Thantawi N,”Analysis For RSG-GAS Operation Characterictic of Reactor Cooling System”, Prosiding Seminar Hasil Penelitian PRSG, p.303, 1998.


Suroso,”Comprehensive Evaluation of Secondary Cooling System of RSG-GAS”, prosiding Seminar Hasil Penelitian P2TRR, p.109, 2005.


[3] Dibyo S,”Validation of RSG-GAS Cooling System Model at Steady-State for the RELAP5. Mod3’, Jurnal Teknologi Reaktor Nuklir; v.7(2); ISSN 1411-240X; Jun 2005.


[4] Iman K,”Evaluation on the Performance of Safety Systems of the RSG-GAS Reactor during 25 Years Operation”, Bulletin of Nuclear Reactor Operation, p.1-10, Vol.11, No.1 2014.


[5] Durgesh B. et.al,”Shell and Tube Heat Exchanger Performance Analysis”, International Journal of Science and Research (IJSR), Vol.3 Issue 9, Sept 2014,


[6] Purwadi MD,“Approach to the Aging Management of RSG-GAS”, Prosiding Seminar Hasil Penelitian PRSG, p.161, 2005.

[7] Herry Hartis,”Unsteady-State Simulation Using CHEMCAD”, Process Engineering Associates, LLC June 2008.


[8] Invap, Reactor Cooling System and Connected Systems, RRRP-7225-SAR Chapter 6, ANSTO, Nov-2004.


[9] prsg, LAK RSG-GAS, Chapter. 6, Rev. 10, 2011.


[10] Solanki K et.al,”Process Optimization Using ChemCad”, Special Issue Azeotrope Vol:I, Issue:II Pub:2014, Page: 47-51, International Journal of Futuristic Trends in Eng. and Tech.


[11] Bhattarai M et.al,”Design of Shell-Tube Heat Exchanger (1-shell series & 1-shell parallel)”, INROADS-An International Journal of Jaipur National University, Vol3, Issue:1st, 2014.


[12] Akram W.et.al,”Thermo-Hydraulic Behavior of Water Cooling Channel Subjected to Constant Heat Flux during Pressure Reduction Transient in its Cooling System”, International Journal of Computer Applications (0975–8887) Vol 80, No 1, October 2013.


[13] Gartman T.N et.al,” Experience in the application of the CHEMCAD program to the modeling of reactor processes”, Theoritical Fundations of Chem.Engineering, Vol.43, No.6, 2009.


[14] Sudiyono,”Cooling System of The RSG-GAS, A Study of Disabilities”, prosiding Seminar Teknologi Pendayagunaan Reaklor Riset G. A. Siwabessy; 130-137, 1995.


[15] Dibyo S,” Assessment Of Heat Loss For RSG-GAS Primary Cooling System” Prosiding Seminar Hasil Penelitian PRSG1998.


[16] Dibyo S,”Analysis of Tube Plugging of the RSG-GAS Reactor Heat Exchangers”, Jurnal Tekn. Reaktor Nuklir Vol. 9 No. 3 Oktober 2007.


[17] Slamet W,”Influence Of Fork-Absorber Test On Core Reactivity And Power Calibration RSG-GAS”, Prosiding Seminar Penelitian Dan Pengelolaan Perangkat Nuklir, PTAPB, p.323, Yogyakarta, 27 Juli 2011.